Routine Name: setclock
Description: Sets time interval (step size) associated with specified clock.
Usage: setclock clock-number value
Example: setclock 0 0.01 // simulation time step in msec
setclock 1 0.05 // plotting interval can be larger
genesis > setclock 0 5.5
changing clock [0] from 1 to 5.5
Notes: The setclock routine is used to set the current value
assigned to the time increment for one of the GENESIS
simulator clocks. These clocks are updated each time a step
is performed.
Clock number 0 is the default clock used by each element to
determine how often it should perform a simulation step. When
components of a simulation run at significantly different time
scales, it may be useful to use other clocks (specified with
useclock) having different time intervals.
See also: showclocks, useclock, getclock